Description
-
- Supply Voltage: 12 V – 24 V AC ±10% (50–60 Hz) / 12 V – 30 V DC ±10%.
- Power Consumption: < 2.5 W.
- Mounting Height: 2 m to 3.5 m.
- Temperature Range: -25°C to +55°C (0–95% relative humidity, non-condensing).
- Protection Degree: IP54 (IEC/EN 60529).
- Dimensions: 264 mm (W) × 58 mm (H) × 58 mm (D).
- Opening / Activation: Unidirectional microwave Doppler radar operating at 24.150 GHz.
- Safety / Presence: Active infrared (AIR) with background analysis. Consists of 2 curtains with up to 24 spots per curtain.
- Min. Detection Speed: 5 cm/s.
- Response Time: Typical < 200 ms (max. 500 ms).
-
- Solid-State Relay: Potential- and polarity-free. Max contact current: 100 mA, Max contact voltage: 42 V AC/DC.
- Output Modes:
-
- Standard switching mode (NO/NC).
- Frequency mode (pulsed signal at 100 Hz ±10%). [1]
-
- Emergency Exit Output: Galvanically isolated current source (Emergency monitoring feature).
- Test Input: Sensitivity: Low < 1 V / High > 10 V (max 30 V). Response time: < 5 ms.
- Norm Conformity: Fully complies with EN 16005, DIN 18650-1, EN ISO 13849-1 (PL «d» CAT. 2), and AutSchR. Suitable for emergency escape routes.






Reviews